p
     
     
 
  p GS550 Display Receiver
p Anti-Two Block Switches
p Wind Speed
p Wireless Angle Sensor
p Wireless Load Cells
p Wireless Load Pins
p Wireless Cable Reel
p Wireless Line Rider
p SMIE Zoning / Anti-Collision
 
 
 
     
 

LSI
 

Wireless Load Cells

LSI Wireless Load Cells provide users with the following features:

pStandard single part line pull sizes include: 5,000 lb, 12,000 lb, 18,000 lb, 35,000 lb, 60,000 lb,      100,000 lb, 170,000 lb
pDirect Sequence-Spread Spectrum-Two Way Communication
pTransmission Range: 3,200 feet; 1,000 meters
pShips as standard with 1-"D" Cell lithium battery, 2-4 years battery life
pUsers can replace lithium battery with "D" Cell alkaline battery if lithium replacement battery is      unavailable when battery goes low. Battery life is 6 months to 1 year using alkaline
pEach load cell ships pre-calibrated eliminating the needs for test weights
pEach load cell is temperature compensated for increased accuracy
pFor crane applications the load cell can be mounted above a ball, odd parted on the block or      even parted at the boom tip
pPotted electronics for increased water proof protection
pOperating temperature: -30F to +180F; -35C to +85
p2 year warranty against defects
pAccuracy is .1% on a single part of line, 1% on a multi part
pCustom sizes on request
pEach load cell is made as standard from 17-4 stainless steel
pExternal antenna increases transmission range as compared to internal antenna
pUser replaceable antenna

   
p